Showing 17–32 of 46 results
Asbestos tops mounted on mild steel tubular stand. Provided with condenser clamps and water manifold.
Other specifications as above.
1. Unit of 3 tests (Heater type)
2. Unit of 6 tests (Heater type)
3. Unit of 3 tests (Mantel type)
4. Unit of 6 tests (Mantel type)
OPTIONAL (Extra cost) Sunvic energy regulator
Add to cart read more.
Laminar flow principle involves double filteration of air through coarse pre- filters (upto 5 microns) and Hepa filter (down to 0.3 microns) for filteration of biological and particulate contaminants. A constant uni-directional air flow is drawn from atmosphere and passed through pre and hepa filters on the work surface. Fabricated out of reinforced ply board which is clad in from out side laminated sheet and inner exposed areas are finished in epoxy paint. Table top covered with non-glaring laminated sheet or stainless steel sheet (optional). Side panels are fixed and are made out transparent acrylic sheet. The front door is folding type and made of thick acrylic sheet. (optional) Stand is built in type or detachable. Blower unit has AU or equilavent motor and is dynamically balanced with minimal sound & vibration level. Fluorescent lighting is also provided. A suitable UV tube is provided for sterilization. An acrylic block type manometer to measure static pressure in the chamber has been inustalled.Two way gas tap for gas line has also been provided
Add to cart read more.
Visualization Technique Suitable for Dark Colored / any colored samples. Silicon Oil Bath Heating Type, Temp. Range : Up to 300ºC, Suitable for Melting / Boiling Point, Readability in ºC, Resolution 1ºC, Programmable, Visual provision by Optical Magnifier, Automatic Ramp Rate Proceeding, Auto Gradient Rate of Heating Control, Sample Capacity 3 samples.
The unit consists of a built in magnetic stirrer, glare free background illuminator and cylindrical silicon oil bath. The silicon oil bath consists of a plain cylindrical container of corning glass having capacity of about 200 ml. It is furnished with a Ptfe cover fitted with special type of oil immersion heater, having three small holes for holding the capillaries, one big hole for thermometer and another big hole for boiling point tube / Temp. Sensors for calibration purposes. A variable speed stirrer is fitted in it. The apparatus can be used for determination of boiling points, Temp. effect on viscosity /flow points and molecular weights by Rast’s method with suitable accessories.
Melting View : Magnifying display of melting operation with the help of adjustable magnifying glass, Melting point reading hold on by activating the “HOLD” key & reading is protected from power failure till “RESET” is not activated.
Add to cart read more.
It constitutes of a washing cylinder made of stainless steel sheet highly polished measuring 63 cm. In height and 15 cm. In diameter and is mounted on a base of 26 cm. diameter. it is provided with a removable pipette holder. It can accommodate pipette of 37.5cm length. It works on the siphoning principle.
Add to cart read more.
Designed for shaking khan racks, bottles, and flasks of different sizes by adjusting compartments. Fitted with heavy duty motor to work on 220 V AC 50 Hz V A single phase. The rate of motion is Adjustable mechanically by belt tension. Speed is fixed in same models to approximately 275 or variable as detailed below.
Add to cart read more.
CENTRIFUGE RECTANGULAR: (RESEARCH) 4000 to 5000 r.p.m. fitted with electronic solid state speed regulator. Top cover made of transparent acrylic sheet, cord & plug. Capacity. a. 4x15ml tubes. b. 6x15ml tubes. c. 8x15ml tubes. d. 12x15ml tubes. Optional :- i) Automatic Timer (Manual). ii) Automatic timer (Digital) iii) Speed Meter ( Manual) iv) Speed Meter (Digital)
Add to cart read more.